How to reduce crosstalk between power FTU modules?

Time:2025-09-18 Views:501次
Share:

Inter-module crosstalk mainly occurs through power supply and interface coupling. Mitigation solutions include:

Independent power supply: Each module uses an independent DC-DC converter, such as the WRB2405S-3W, with an isolation voltage of 1500VDC.

Interface isolation: Inter-module communication uses an ADUM1410 digital isolator (3kVrms).

PCB design: Modules are isolated using a 2mm wide grounded guard ring. Interface signal lines use differential transmission with 100Ω impedance matching. Metal partitions, 0.8mm thick, are added between modules inside the chassis.