Ground loop interference in EPS originates from potential differences between different grounding points or from the loop picking up spatial magnetic fields, inducing common-mode noise in the signal loop. Methods to eliminate this interference from the electronic circuit end include:
1. Loop interruption: Using common-mode chokes on susceptible analog signal lines and communication lines, such as CML series common-mode inductors on sampling or RS485 lines, to suppress common-mode interference without affecting differential signals.
2. Electrical isolation: Using optocouplers, isolation operational amplifiers, or digital isolators to completely disconnect the direct connection of the signal ground wire; this is one of the most effective methods.
3. Differential transmission: For analog signals, using differential amplifiers and twisted-pair transmission utilizes their high common-mode rejection ratio (CMRR) to cancel loop-induced noise.
4. Single-point grounding: In system design, planning single-point grounding for low-frequency analog circuits to avoid ground loop formation at its source.