The isolation method between the HMI communication interface ground and the chassis ground depends on the product safety standards, interface type, and immunity requirements. Common isolation strategies include: direct connection, connection via capacitor, connection via resistor/ferrite bead, or complete floating. For protective grounding equipment, the chassis ground is usually directly connected to earth ground, while the communication signal ground may be connected to the chassis ground at a single point via a ferrite bead or 0Ω resistor. This provides a DC reference and isolates high-frequency noise to some extent. For floating ground equipment or applications requiring enhanced common-mode interference immunity, the communication signal ground is usually connected to the chassis ground via a safety-certified Y capacitor.
The Y capacitor value is typically between 1nF and 4.7nF. This allows high-frequency interference to be discharged to the chassis through the capacitor, while DC and low-frequency signals are isolated, avoiding ground loops. For interfaces with high isolation requirements, such as medical equipment or certain industrial environments, isolated communication chips are used. In this case, the signal ground on the interface side is completely independent, isolated from the internal ground of the equipment by an isolation barrier, and the signal is coupled only through an isolation capacitor or transformer. When selecting an isolation method, it is necessary to comprehensively consider the requirements of safety standards such as IEC 60601 regarding patient leakage current, as well as the requirements of IEC 61000-4 series standards regarding EMC immunity. Etymotic can provide ferrite beads for grounding connections, safety Y capacitors, and isolated communication solutions to help achieve a balance between safety and EMC.