To ensure EPS meets the conducted and radiated emission limits of CISPR 11 (GB4824), systematic suppression measures are required. Conducted emission (CE) compliance relies on effective input/output EMI filters, good grounding, and optimized PCB layout. Radiated emission (RE) compliance relies more heavily on shielding and layout:
1. Source suppression: Optimize switching device drive to reduce dv/dt and di/dt; employ soft-switching technology; minimize power loop area.
2. Comprehensive shielding: Use a complete metal cabinet and ensure shielding continuity at all seams and openings (vents, cable entry points) (using gaskets, waveguide windows, shielded connectors).
3. Cable handling: All incoming and outgoing cables must be shielded, and the shielding layer should be lapped and grounded 360 degrees at the cabinet entry point. Use ferrite cores on necessary cables.