The grounding method of industrial AI edge gateways directly affects the AI module's immunity and radiated emissions. A hybrid grounding approach is recommended. The low-frequency single-point signal ground (GND) is connected to the chassis ground (PE) at a single point via a ferrite bead (PBZ1608E600Z0T). The AI module's digital ground is connected to the motherboard ground plane via a via array with low resistance. The I/O interface ground is connected to PE via a 1nF 2kV Y capacitor. Actual testing showed that using a floating ground resulted in a 30% EFT ±2kV reset probability for the AI module. After adopting hybrid grounding, the reset probability was 0%, and radiated emissions were reduced by 8dB.