How can the EMC limits for power transmission from a power DTU be met?

Time:2025-12-21 Views:505次
Share:

Compliance with DTU power transmission EMC limits must be controlled from the design stage. Conducted emission limits refer to GB 9254 Class B, with an average limit of 56-60 dBμV and a quasi-peak limit of 66-70 dBμV in the 150kHz-30MHz frequency band. During design, deploy high-performance EMI filters, such as CML4532A-510T, and safety capacitors at the power line inlet. Radiated emission limits are 30-40 dBμV/m in the 30MHz-1GHz frequency band, measured at a distance of 10m. Suppress radiation through shielding housings and filtered connectors. Pre-testing uses an EMI receiver, optimizing the design margin to greater than 6dB. Compliance with limits allows for certification testing and legal sale of the product.