| Serial Number | Test Object | Project/Parameter | Test Standard (Method) | Description |
| No. | Name |
| 1 | Electronic and Electrical Components, Semiconductor Discrete Devices and Integrated Circuits | 1 | Capacitance Measurement | Test Methods for Electronic and Electrical Components GJB 360B-2009 Method 305 | Only measure: Frequency: 20Hz~1MHz. |
| 2 | Physical Dimensions | Test Methods for Semiconductor Discrete Devices GJB 128B-2021 Method 2066 | |
| 3 | Forward Voltage | Semiconductor Devices Discrete Devices and Integrated Circuits Part 2: Rectifier Diodes GB/T 4023-2015 7.1.2.1 | Only measure: Forward voltage ≤4V, Forward current ≤25A. |
| Test Methods for Semiconductor Discrete Devices GJB 128B-2021 Method 4011 | Only measure: Forward voltage ≤4V, Forward current ≤25A; Clause 3.1 (DC Method) |
| 4 | Breakdown Voltage | Semiconductor Devices Discrete Devices and Integrated Circuits Part 2: Rectifier Diodes GB/T 4023-2015 7.1.3 | Only measure: Below 2200V. |
| Test Methods for Semiconductor Discrete Devices GJB 128B-2021 Method 4021 | Only measure: Below 2200V. |
| 5 | Reverse Leakage Current | Test Methods for Semiconductor Discrete Devices GJB 128B-2021 Method 4016 | Only measure: Voltage ≤2200V, Current ≤9.99mA; Clause 2 (DC Method) |
| Semiconductor Devices Discrete Devices and Integrated Circuits Part 2: Rectifier Diodes GB/T 4023-2015 7.1.4.1 | Only measure: Voltage ≤2200V, Current ≤9.99mA. |
| 6 | Load Dump Test | Road Vehicles Environmental Conditions and Testing for Electrical and Electronic Equipment Part 2: Electrical Loads GB/T 28046.2-2019 4.6.4 | |
| 7 | Overvoltage | Road Vehicles Environmental Conditions and Testing for Electrical and Electronic Equipment Part 2: Electrical Loads GB/T 28046.2-2019 4.3 | |
| 8 | Reverse Voltage | Road Vehicles Environmental Conditions and Testing for Electrical and Electronic Equipment Part 2: Electrical Loads GB/T 28046.2-2019 4.7 | |
| 9 | Open Circuit Test | Road Vehicles Environmental Conditions and Testing for Electrical and Electronic Equipment Part 2: Electrical Loads GB/T 28046.2-2019 4.9 | |
| 10 | Short Circuit Protection | Road Vehicles Environmental Conditions and Testing for Electrical and Electronic Equipment Part 2: Electrical Loads GB/T 28046.2-2019 4.10 | |
| 11 | Withstand Voltage | Road Vehicles Environmental Conditions and Testing for Electrical and Electronic Equipment Part 2: Electrical Loads GB/T 28046.2-2019 4.11 | |
| 12 | High Temperature Reverse Bias Test | Semiconductor Devices Environmental Test Methods Part 1: Test Methods 1000 to 1999 MIL-STD-750-1B-2022 1038.5 | Only measure: Clause a (HTRB); High temperature ≤175℃; Chamber volume size: (Height×Width ×Depth) (1100mm×580mm×630mm). |
| Failure Mechanism Based Stress Test Qualification for Automotive Discrete Semiconductor Devices AEC-Q101-Rev-E:2021 4.1 | Only measure: HTRB; High temperature ≤175℃; Chamber size (Height×Width×Depth) (1100mm×580mm×630mm) |
| 2 | Electronic Products | 1 | Constant Temperature Test | Road Vehicles Environmental Conditions and Testing for Electrical and Electronic Equipment Part 4: Climatic Loads GB/T 28046.4-2011 5.1 | Only measure: Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm); Temperature range -40℃~150℃. |
| 2 | Temperature Gradient | Road Vehicles Environmental Conditions and Testing for Electrical and Electronic Equipment Part 4: Climatic Loads GB/T 28046.4-2011 5.2 | Only measure: Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm); Temperature range -40℃~150℃. |
| 3 | Damp Heat Cycling | Road Vehicles Environmental Conditions and Testing for Electrical and Electronic Equipment Part 4: Climatic Loads GB/T 28046.4-2011 5.6 | Only measure: Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm); Temperature range -40℃~150℃; Temperature/Humidity: 85℃/85%RH, 40℃/93%RH, 25℃/95%RH, 55℃/93%RH; Test 1. |
| Road Vehicles Environmental Conditions and Testing for Electrical and Electronic Equipment Part 4: Climatic Loads ISO 16750-4:2006 5.6 | Only measure: Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm); Temperature range -40℃~150℃; Temperature/Humidity: 85℃/85%RH, 40℃/93%RH, 25℃/95%RH, 55℃/93%RH; Test 1. |
| 4 | Steady Damp Heat | Road Vehicles Environmental Conditions and Testing for Electrical and Electronic Equipment Part 4: Climatic Loads GB/T 28046.4-2011 5.7 | Only measure: Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm); Temperature/Humidity: 85℃/85%RH, 40℃/93%RH, 25℃/95%RH, 55℃/93%RH, 40℃/85%RH, 30℃/93%RH, 30℃/85%RH. |
| Road Vehicles Environmental Conditions and Testing for Electrical and Electronic Equipment Part 4: Climatic Loads ISO 16750-4:2006 5.7 | Only measure: Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm); Temperature/Humidity: 85℃/85%RH, 40℃/93%RH, 25℃/95%RH, 55℃/93%RH, 40℃/85%RH, 30℃/93%RH, 30℃/85%RH. |
| 5 | Constant Damp Heat Test | Environmental Testing Part 2: Test Methods Test Cab: Constant Damp Heat Test GB/T 2423.3-2016 | Only measure: Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm); Temperature/Humidity: 85℃/85%RH, 40℃/93%RH, 25℃/95%RH, 55℃/93%RH, 40℃/85%RH, 30℃/93%RH, 30℃/85%RH. |
| 6 | Constant Damp Heat | Environmental Testing Part 2: Test Methods Test Cy: Constant Damp Heat Mainly for Accelerated Testing of Components GB/T 2423.50-2012 | Only measure: Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm); Temperature/Humidity: 85℃/85%RH. |
| 7 | Alternating Damp Heat (12h+12h Cycle) | Electrical and Electronic Products Environmental Testing Part 2: Test Methods Test Db: Alternating Damp Heat (12h+12h Cycle) GB/T 2423.4-2008 | Only measure: Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm); Temperature/Humidity: 85℃/85%RH, 40℃/93%RH, 25℃/95%RH, 55℃/93%RH. |
| 8 | Damp Heat Test | Military Equipment Laboratory Environmental Test Methods Part 9: Damp Heat Test GJB 150.9A-2009 | Only measure: Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm); Temperature/Humidity: 85℃/85%RH, 40℃/93%RH, 25℃/95%RH, 55℃/93%RH. |
| 9 | High Temperature Test | Electrical and Electronic Products Environmental Testing Part 2 Test Methods Test B: High Temperature GB/T 2423.2-2008 | Only measure: Bb (Clause 5.2); Temperature range room temperature~150℃; Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm) |
| Military Equipment Laboratory Environmental Test Methods Part 3: High Temperature Test GJB 150.3A-2009 7 | Only measure: Temperature range room temperature~150℃; Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm). Not measure: Clause 4.3.3.3 (Special Conditions). |
| High Temperature Storage Life JESD22-A103E.01-2021 4 | Only measure: Temperature: 125℃~150℃; Chamber volume size: (Height×Width×Depth) (500mm×400mm×500mm); Conditions A and B. |
| 10 | Low Temperature Test | Electrical and Electronic Products Environmental Testing Part 2: Test Methods Test A: Low Temperature GB/T 2423.1-2008 | Only measure: Ab (Clause 5.2); Temperature range -40℃~+5℃; Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm) |
| Military Equipment Laboratory Environmental Test Methods Part 4: Low Temperature Test GJB 150.4A-2009 7 | Only measure: Temperature range -40℃~+5℃; Chamber volume size (Height×Width×Depth) (500mm×400mm×500mm) |
| Low Temperature Storage Life JESD22-A119A-2015 | Only measure: Temperature: -40℃; Chamber volume size: (Height×Width×Depth) (500mm×400mm×500mm) |
| 11 | Electrostatic Discharge Immunity | Electromagnetic Compatibility Testing and Measurement Techniques Electrostatic Discharge Immunity Test GB/T 17626.2-2018 | |
| 12 | Surge (Impact) Immunity | Electromagnetic Compatibility Testing and Measurement Techniques Surge (Impact) Immunity Test GB/T 17626.5-2019 | Not measure: Three-phase products; Communication ports. |
| 13 | Electrical Fast Transient/Burst Immunity | Electromagnetic Compatibility Testing and Measurement Techniques Electrical Fast Transient/Burst Immunity Test GB/T 17626.4-2018 | Not measure: Three-phase products. |